TROUBLE
|
PROBABLE CAUSE
|
RECOMMENDED REMEDY
|
| (1) Conveyor stops without control depressing
secondary "STOP". |
a. Blown fuses in transformer. |
a. Check and replace blown (F-1) fuses.
Ascertain cause. |
| |
b. Motor overload causing magnetic starter
to trip. |
b. Reset magnetic overload. |
| (2) Excessive noise or vibration
from motor or reducer. |
a. Loose mounting. |
a. [LOCK
OUT UNIT.] Check motor mounting bolts for tightness. Feel if mounting
plate is secure. Tighten as required. |
| (3) Oil leakage from |
a. Loose drain plug - damaged seal. |
a. [LOCK OUT UNIT.]
Tighten drain plug or replace if threads are damaged. Disassemble gearcase
to replace seals. |
| |
b. Cracked reducer housing. |
b. Drain and remove gearmotor or gearcase.
Install replacement unit. |
| |
c. Unit over filled. |
c. Remove excess oil. |